Industrial Automation

Pneumatic • Instrumentation • Automatisms • Smarthome

Home Q2A Frequency inverter
Q2A Tailored application frequency inverter
Frequency inverter Omron Q2A

 

Efficiency, flexibility and ease of use thanks to the simple philosophy "program, implement and go"


The new Omron frequency inverter Q2A for custom applications minimizes the space occupied and the hardware cost, reduces the time of design and start-up, and offers an improved performance for different types of motors. You can optimize the entire application workflow: Design, commissioning, maintenance and production adjustment.


Open / closed loop speed or torque control

Embedded functional safety (STO SIL3)

Built-in C3 class EMC filter

Conform to EN 60721-3-3, 3S2 and 3C2

Built-in braking transistor (up to 90 kW)

Quick and easy setup with intuitive keypad and navigation

Micro SD for data storage

Real-Time Clock

24 VDC power supply input for control board

Mobile Device connectivity (via USB or optional Bluetooth)

CE, UL, cUL, EAC, RoHS


Improved motor performance


Q2A series is able to control different motor types in open and closed loops

Can control a wide variety of motors, such as IM, SPM, IPM, DDPM and SynRM

Up to 590 Hz as standard

Zero speed control without encoder

Tuning-less with EZ vector


Network integration and Energy efficiency

Omron frequency inverter Q2A Energy Integration

Up to 5 Q2A with a single communication option card. Flexibility in communications by being compatible with many communication options based on Ethernet, such as the EtherCAT connection used by the Omron Sysmac system, and connections such as Ethernet / IP, PROFINET and POWERLINK.


Q2A drive series combined with D1000 or R1000 units can solve regenerative applications re-using the energy for other applications within the same installation.


Characteristics


Voltage: 400V

Model Heavy Duty
< 460 V
Max. Motor
(kW)
Rated
Output
Current (A)
Inverter
Capacity
(kVA)
Input
Power
(kVA)
Q2A-A4002 0.55 1.8 1.2 1.5
Q2A-A4004 0.75 3.4 2.2 2.8
Q2A-A4005 1.5 4.8 3.2 3.7
Q2A-A4007 2.2 5.5 3.6 5.3
Q2A-A4009 3.0 7.2 4.7 7.1
Q2A-A4012 3.7 9.2 6.1 9.3
Q2A-A4018 5.5 14.8 10 13
Q2A-A4023 7.5 18 12 17
Q2A-A4031 11 24 16 24
Q2A-A4038 15 31 20 33
Q2A-A4044 18.5 39 26 40
Q2A-A4060 22 45 30 34
Q2A-A4075 30 60 39 46
Q2A-A4089 37 75 49 57
Q2A-A4103 45 91 60 69
Q2A-A4140 55 112 74 84
Q2A-A4168 75 150 99 113
Q2A-A4208 90 180 118 136
Q2A-A4250 110 216 142 165
Q2A-A4296 132 260 171 198
Q2A-A4371 160 304 200 239
Q2A-A4389 200 371 244 297
Q2A-A4453 220 414 272 327
Q2A-A4568 250 453 298 370
Q2A-A4675 315 605 398 465

Characteristics


Voltage: 400V

Model Normal Duty
< 460 V
Max. Motor
(kW)
Rated
Output
Current (A)
Inverter
Capacity
(kVA)
Input
Power
(kVA)
Q2A-A4002 0.75 2.1 1.4 2.0
Q2A-A4004 1.5 4.1 2.7 3.7
Q2A-A4005 2.2 5.4 3.6 5.3
Q2A-A4007 3.0 7.1 4.7 7.1
Q2A-A4009 3.7 8.9 5.9 9.3
Q2A-A4012 5.5 11.9 7.8 13
Q2A-A4018 7.5 17.5 12 17
Q2A-A4023 11 23.4 15 24
Q2A-A4031 15 31 20 33
Q2A-A4038 18.5 38 25 40
Q2A-A4044 22 44 29 48
Q2A-A4060 30 59.6 39 46
Q2A-A4075 37 74.9 49 57
Q2A-A4089 45 89.2 59 69
Q2A-A4103 55 103 68 84
Q2A-A4140 75 140 92 113
Q2A-A4168 90 168 111 136
Q2A-A4208 110 208 137 165
Q2A-A4250 132 250 165 198
Q2A-A4296 160 296 195 239
Q2A-A4371 200 371 244 297
Q2A-A4389 320 389 256 327
Q2A-A4453 250 453 298 370
Q2A-A4568 315 568 374 465
Q2A-A4675 355 675 444 523

Characteristics


Voltage: 400V

Model Heavy Duty
≥ 460 V
Max. Motor
(kW)
Rated
Output
Current (A)
Inverter
Capacity
(kVA)
Input
Power
(kVA)
Q2A-A4002 0.55 1.6 1.3 1.3
Q2A-A4004 0.75 2.1 1.7 1.7
Q2A-A4005 1.5 3.4 2.7 3.2
Q2A-A4007 2.2 4.8 3.8 4.6
Q2A-A4009 3.0 6.9 5.5 6.1
Q2A-A4012 3.7 7.6 6.1 7.5
Q2A-A4018 5.5 11 8.8 11
Q2A-A4023 7.5 14 11 15
Q2A-A4031 11 21 17 21
Q2A-A4038 15 27 22 28
Q2A-A4044 18.5 34 27 35
Q2A-A4060 22 40 32 30
Q2A-A4075 30 52 41 40
Q2A-A4089 37 65 52 49
Q2A-A4103 45 77 61 59
Q2A-A4140 55 96 76 72
Q2A-A4168 75 124 99 98
Q2A-A4208 90 156 124 117
Q2A-A4250 110 180 143 142
Q2A-A4296 150 240 191 193
Q2A-A4371 185 302 241 240
Q2A-A4389 220 361 288 288
Q2A-A4453 260 414 330 335
Q2A-A4568 300 477 380 382
Q2A-A4675 335 515 410 429

Characteristics


Voltage: 400V

Model Normal Duty
≥ 460 V
Max. Motor
(kW)
Rated
Output
Current (A)
Inverter
Capacity
(kVA)
Input
Power
(kVA)
Q2A-A4002 0.75 2.1 1.7 2.1
Q2A-A4004 1.5 3.0 2.4 4.0
Q2A-A4005 2.2 4.8 3.8 5.6
Q2A-A4007 3.0 6.9 5.5 7.5
Q2A-A4009 3.7 7.6 6.1 9.1
Q2A-A4012 5.5 11 8.8 13
Q2A-A4018 7.5 14 11 18
Q2A-A4023 11 21 17 26
Q2A-A4031 15 27 22 35
Q2A-A4038 18.5 34 27 42
Q2A-A4044 22 40 32 50
Q2A-A4060 30 52 41 49
Q2A-A4075 37 65 52 60
Q2A-A4089 45 77 61 73
Q2A-A4103 55 96 76 88
Q2A-A4140 75 124 99 120
Q2A-A4168 90 156 124 143
Q2A-A4208 110 180 143 174
Q2A-A4250 150 240 191 236
Q2A-A4296 185 302 241 295
Q2A-A4371 220 361 288 352
Q2A-A4389 260 414 330 410
Q2A-A4453 300 477 380 468
Q2A-A4568 335 515 410 526
Q2A-A4675 370 605 482 584

Specifications


Voltage: 400V

Overload tolerance Heavy Duty: 150% of the rated output current for 60 seconds
Normal Duty: 110% of the rated output current for 60 seconds
Max. output voltage Proportional to input voltage: 380-480 V
Max. output frequency AOLV, EZOLV: 120 Hz
CL-V/f, CLV, AOLV/PM, CLV/PM: 400 Hz
V/f, OLV, OLV/PM: 590 Hz
Rated voltage and frequency 3-phase AC power supply 380-480 V at 50/60 Hz
DC power supply 513-679 VDC
Allowable voltage fluctuation −15% a +10%
Allowable frequency fluctuation ±5%

System Configuration


Frequency inverter Omron Q2A System Configuration

PC Software Q2edit

Omron Q2dev and Q2edit

Graphical setup, Q2edit software tool provides parameter setting and monitoring for computers and smart devices.


PC Software Q2dev

Omron Q2dev and Q2edit

Optimize your engineering time. Q2dev provides faster application customization.


Documentation



Open PDF

Q2A Datasheet


Open PDF

Q2A Brochure


Open PDF

Q2A Installation & Operation Instructions


Open PDF

Q2A Technical Manual

DISTRIBUTION

THE BEST BRANDS

Automatism, Pneumatic and Smarthome


Distribution
distribution

THE BEST BRANDS

Automatism, Pneumatic and Smarthome


Distribution
ENGINEERING

ENGINEERING

We take the hand of your project and we guide it to the right place

Engineering

Share this page

Top